{"id":1403,"date":"2025-07-16T12:26:22","date_gmt":"2025-07-16T12:26:22","guid":{"rendered":"https:\/\/virtualall.sk\/?p=1403"},"modified":"2026-09-11T14:38:30","modified_gmt":"2026-09-11T14:38:30","slug":"cisco-ucs-c220-m7-ako-management-server-sietova-architektura-pre-vmware-klaster-part-3","status":"publish","type":"post","link":"https:\/\/virtualall.sk\/en\/2025\/07\/cisco-ucs-c220-m7-ako-management-server-sietova-architektura-pre-vmware-klaster-part-3\/","title":{"rendered":"Cisco UCS C220 M7 Network Architecture Part 3"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">V predch\u00e1dzaj\u00facej \u010dasti sme sa venovali v\u00fdberu hardv\u00e9rovej platformy Cisco UCS C220 M7 ako z\u00e1kladn\u00e9ho prvku pre budovanie bezpe\u010dn\u00e9ho a vysoko dostupn\u00e9ho VMware klastra ur\u010den\u00e9ho pre management a z\u00e1lohovanie. V tejto \u010dasti sa zameriame na n\u00e1vrh a implement\u00e1ciu sie\u0165ovej architekt\u00fary, ktor\u00e1 tvor\u00ed chrbticu ka\u017edej virtualizovanej infra\u0161trukt\u00fary. Spr\u00e1vne navrhnut\u00e1 sie\u0165 nie je len o redundancii, ale predov\u0161etk\u00fdm o optimaliz\u00e1cii d\u00e1tov\u00fdch tokov, oddelen\u00ed prev\u00e1dzky, \u0161k\u00e1lovate\u013enosti a jednoduchosti spr\u00e1vy. Cisco UCS C220 M7 servery boli zapojen\u00e9 do dvojice Cisco Nexus switchov s cie\u013eom zabezpe\u010di\u0165 vysok\u00fa dostupnos\u0165 v sie\u0165ovej vrstve. Ka\u017ed\u00fd server je pripojen\u00fd dvoma samostatn\u00fdmi 25 Gbit linkami, z ktor\u00fdch ka\u017ed\u00e1 smeruje do in\u00e9ho Nexus switcha, \u010d\u00edm sa eliminuje riziko v\u00fdpadku siete pri zlyhan\u00ed jedn\u00e9ho prep\u00edna\u010da. Navy\u0161e, servery s\u00fa medzi sebou prepojen\u00e9 dvoma dedikovan\u00fdmi 25 Gbit linkami, ktor\u00e9 sl\u00fa\u017eia v\u00fdlu\u010dne na intern\u00fa komunik\u00e1ciu v r\u00e1mci VMotion a Storage vMotion \u2013 teda na \u00fa\u010dely migr\u00e1cie virtu\u00e1lnych strojov a ich diskov\u00fdch objemov bez ovplyvnenia prev\u00e1dzky produk\u010dn\u00fdch siet\u00ed. Ka\u017ed\u00fd server disponuje dvoma fyzick\u00fdmi sie\u0165ov\u00fdmi kartami \u2013 VIC 15425 a MLOM \u2013 ktor\u00e9 s\u00fa zapojen\u00e9 redundantne a pracuj\u00fa v re\u017eime Physical NIC Mode. Tento re\u017eim umo\u017e\u0148uje transparentn\u00e9 pren\u00e1\u0161anie VLAN zna\u010diek bez z\u00e1sahov zo strany ASIC \u010dipu sie\u0165ovej karty, \u010d\u00edm je dosiahnut\u00e1 maxim\u00e1lna flexibilita v spr\u00e1ve sie\u0165ovej segment\u00e1cie priamo v prostred\u00ed VMware. Zvolen\u00e1 topol\u00f3gia a architekt\u00fara tak vytv\u00e1ra pevn\u00fa a flexibiln\u00fa infra\u0161trukt\u00faru pripraven\u00fa na prev\u00e1dzku kritick\u00fdch syst\u00e9mov\u00fdch slu\u017eieb aj ich bud\u00face \u0161k\u00e1lovanie.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Topol\u00f3gia pripojenia<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ka\u017ed\u00fd z dvoch serverov Cisco UCS C220 M7 je pripojen\u00fd <strong>redundantne do dvoch Cisco Nexus switchov<\/strong>, \u010d\u00edm je zabezpe\u010den\u00e1 vysok\u00e1 dostupnos\u0165 sie\u0165ovej vrstvy:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ka\u017ed\u00fd server je pripojen\u00fd <strong>1\u00d7 25 Gbit<\/strong> linkou do <strong>ka\u017ed\u00e9ho z dvoch Nexus switchov<\/strong>.<\/li>\n\n\n\n<li>Medzi servermi s\u00fa priamo vytvoren\u00e9 <strong>2\u00d7 25 Gbit prepoje<\/strong>. Tieto sl\u00fa\u017eia <strong>v\u00fdhradne pre VMotion a Storage vMotion<\/strong>, \u010do zabezpe\u010duje dedikovan\u00fa a vysokokapacitn\u00fa cestu pre migr\u00e1cie VM a prenos diskov\u00fdch obrazov.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-gallery aligncenter has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" data-id=\"1404\" src=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/ChatGPT-Image-16.-7.-2025-13_54_54.png\" alt=\"Topol\u00f3gia pripojenia\" class=\"wp-image-1404\" srcset=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/ChatGPT-Image-16.-7.-2025-13_54_54.png 1024w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/ChatGPT-Image-16.-7.-2025-13_54_54-300x300.png 300w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/ChatGPT-Image-16.-7.-2025-13_54_54-150x150.png 150w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/ChatGPT-Image-16.-7.-2025-13_54_54-768x768.png 768w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/ChatGPT-Image-16.-7.-2025-13_54_54-12x12.png 12w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/ChatGPT-Image-16.-7.-2025-13_54_54-70x70.png 70w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Segment\u00e1cia a \u00fa\u010del siet\u00ed<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Sie\u0165 je logicky rozdelen\u00e1 pod\u013ea funkci\u00ed:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Smer komunik\u00e1cie<\/th><th>Popis<\/th><\/tr><\/thead><tbody><tr><td>Servery \u2194 Nexus switch<\/td><td>Extern\u00e1 komunik\u00e1cia pre VM, pr\u00edstup k internetu, management VMware<\/td><\/tr><tr><td>Servery \u2194 Servery (25G linky)<\/td><td>Dedikovan\u00e1 sie\u0165 pre VMotion a Storage vMotion<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Takto rozdelen\u00e1 architekt\u00fara v\u00fdrazne <strong>zvy\u0161uje v\u00fdkonnos\u0165 a zni\u017euje interferenciu medzi produk\u010dn\u00fdmi a syst\u00e9mov\u00fdmi tokmi d\u00e1t<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Sie\u0165ov\u00e9 adapt\u00e9ry a redundancia<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ka\u017ed\u00fd server je osaden\u00fd dvoma fyzick\u00fdmi sie\u0165ov\u00fdmi kartami:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Cisco VIC 15425<\/strong><\/li>\n\n\n\n<li><strong>MLOM (Modular LAN on Motherboard)<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Obidve sie\u0165ov\u00e9 karty s\u00fa nakonfigurovan\u00e9 <strong>redundantne<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Port z <strong>prvej karty<\/strong> vedie do <strong>prv\u00e9ho Nexus switcha<\/strong><\/li>\n\n\n\n<li>Port z <strong>druhej karty<\/strong> vedie do <strong>druh\u00e9ho Nexus switcha<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e1to konfigur\u00e1cia eliminuje <strong>single point of failure<\/strong> v r\u00e1mci fyzickej sie\u0165ovej vrstvy.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"403\" src=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-30-1024x403.png\" alt=\"Sie\u0165ov\u00e9 adapt\u00e9ry a redundancia\" class=\"wp-image-1405\" srcset=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-30-1024x403.png 1024w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-30-300x118.png 300w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-30-768x302.png 768w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-30-1536x604.png 1536w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-30-18x7.png 18w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-30.png 1859w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Obe sie\u0165ov\u00e9 karty boli nakonfigurovan\u00e9 v re\u017eime:<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>When Physical NIC Mode is enabled, up-link ports of the VIC are set to pass-through mode.<\/strong><br><strong>This allows the host to transmit packets without any modification.<\/strong><br><strong>VIC ASIC does not rewrite the VLAN tag of the packets based on the VLAN and CoS settings for the vNIC.<\/strong><\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Tento re\u017eim som zvolil z d\u00f4vodu <strong>jednoduch\u0161ej spr\u00e1vy VLAN segment\u00e1cie priamo cez VMware vSphere<\/strong>, kde ka\u017ed\u00e1 virtu\u00e1lna sie\u0165 (portgroup) priamo spravuje tagovanie bez potreby \u010fal\u0161\u00edch z\u00e1sahov do sie\u0165ov\u00e9ho adapt\u00e9ra. Znamen\u00e1 to, \u017ee v\u0161etky VLAN tagy s\u00fa <strong>pren\u00e1\u0161an\u00e9 transparentne<\/strong>, bez z\u00e1sahov na \u00farovni hardv\u00e9rov\u00e9ho ASIC-u v sie\u0165ovej karte.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">VMware sie\u0165ov\u00e1 architekt\u00fara: oddelenie produkcie od syst\u00e9mov\u00fdch oper\u00e1ci\u00ed<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Na ka\u017edom zo serverov Cisco UCS C220 M7 je nain\u0161talovan\u00fd <strong>VMware ESXi<\/strong>, pri\u010dom sie\u0165ov\u00e1 architekt\u00fara v r\u00e1mci hyperv\u00edzora je navrhnut\u00e1 s d\u00f4razom na oddelenie prev\u00e1dzky produk\u010dn\u00fdch virtu\u00e1lnych strojov od syst\u00e9movej infra\u0161trukt\u00fary (vMotion, Storage vMotion). Ka\u017ed\u00fd hyperv\u00edzor je nakonfigurovan\u00fd so <strong>dvoma nez\u00e1visl\u00fdmi virtu\u00e1lnymi switchmi<\/strong> (vSwitch), ktor\u00e9 reflektuj\u00fa fyzick\u00fa sie\u0165ov\u00fa segment\u00e1ciu:<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">vSwitch0 \u2013 Produk\u010dn\u00fd prev\u00e1dzkov\u00fd switch<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u00da\u010del<\/strong>: Produk\u010dn\u00fd traffic virtu\u00e1lnych strojov, komunik\u00e1cia s internetom, DNS, Active Directory, pr\u00edstup do LAN<\/li>\n\n\n\n<li><strong>Fyzick\u00e9 uplinky<\/strong>:\n<ul class=\"wp-block-list\">\n<li>1\u00d7 uplink z karty VIC \u2192 Nexus A<\/li>\n\n\n\n<li>1\u00d7 uplink z karty MLOM \u2192 Nexus B<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Portgroupy<\/strong>:\n<ul class=\"wp-block-list\">\n<li><code>VM_Network<\/code> \u2013 Hlavn\u00e1 sie\u0165 pre VM<\/li>\n\n\n\n<li><code>Management<\/code> \u2013 Pr\u00edstup na spr\u00e1vu ESXi (vSphere\/vCenter)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">vSwitch1 \u2013 Syst\u00e9mov\u00fd switch pre vMotion a Storage vMotion<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u00da\u010del<\/strong>: Intern\u00e1 komunik\u00e1cia pre migr\u00e1ciu VM a prenos diskov (bez smerovania do LAN alebo internetu)<\/li>\n\n\n\n<li><strong>Fyzick\u00e9 uplinky<\/strong>:\n<ul class=\"wp-block-list\">\n<li>2\u00d7 25G priame linky medzi servermi (NIC-to-NIC)<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Portgroupy<\/strong>:\n<ul class=\"wp-block-list\">\n<li><code>vMotion_Network<\/code><\/li>\n\n\n\n<li><code>Storage_vMotion_Network<\/code><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00fdmto rozdelen\u00edm dosahujeme:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u00dapln\u00fa fyzick\u00fa a logick\u00fa separ\u00e1ciu trafficu<\/strong> \u2013 produkt\u00edvna prev\u00e1dzka a VM migr\u00e1cie sa nikdy nemie\u0161aj\u00fa.<\/li>\n\n\n\n<li><strong>Zv\u00fd\u0161en\u00fa v\u00fdkonnos\u0165 migr\u00e1ci\u00ed<\/strong> \u2013 linky ur\u010den\u00e9 pre vMotion nie s\u00fa zdie\u013ean\u00e9 s inou prev\u00e1dzkou.<\/li>\n\n\n\n<li><strong>Zv\u00fd\u0161en\u00fa bezpe\u010dnos\u0165<\/strong> \u2013 \u017eiadne d\u00e1ta z vMotion siete nie s\u00fa smerovate\u013en\u00e9 mimo syst\u00e9m.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">D\u00f4le\u017eit\u00e9 nastavenia vo VMware<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Na portgroup\u00e1ch pre <code>vMotion<\/code> a <code>Storage_vMotion<\/code> mus\u00ed by\u0165 aktivovan\u00e1 <strong>vMotion slu\u017eba<\/strong> v <code>VMkernel Adapter<\/code> (VMK).<\/li>\n\n\n\n<li><code>vMotion<\/code> a <code>Storage vMotion<\/code> m\u00f4\u017eu pou\u017e\u00edva\u0165 oddelen\u00e9 VMkernel adapt\u00e9ry, ka\u017ed\u00e9 s vlastn\u00fdm IP rozsahom.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Cel\u00e1 s\u00e9ria: Cisco UCS C220 M7<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n\n<li><a href=\"https:\/\/virtualall.sk\/2025\/07\/cisco-ucs-c220-m7-ako-zaklad-pre-bezpecny-vmware-klaster-pre-management-a-zalohovanie\/\">Cisco UCS C220 M7 VMware klaster<\/a><\/li>\n\n\n<li><a href=\"https:\/\/virtualall.sk\/2025\/07\/cisco-ucs-c220-m7-ako-zaklad-pre-bezpecny-vmware-klaster-pre-management-a-zalohovanie-part-2\/\">Cisco UCS C220 M7 VMware klaster Part 2<\/a><\/li>\n\n\n<li><strong>Cisco UCS C220 M7 sie\u0165ov\u00e1 architekt\u00fara Part 3<\/strong> &mdash; tento \u010dl\u00e1nok<\/li>\n\n\n<li><a href=\"https:\/\/virtualall.sk\/2025\/07\/cisco-ucs-c220-m7-ako-management-server-instalacia-vmware-esxi-a-vcenter-pre-spravu-klastra-part-4\/\">Cisco UCS C220 M7 ESXi a vCenter Part 4<\/a><\/li>\n\n\n<li><a href=\"https:\/\/virtualall.sk\/2025\/07\/cisco-ucs-c220-m7-ako-management-server-konfiguracia-vmware-siete-a-vmotion-part-5\/\">Cisco UCS C220 M7 VMware sie\u0165 a vMotion Part 5<\/a><\/li>\n\n\n<li><a href=\"https:\/\/virtualall.sk\/2025\/07\/cisco-ucs-c220-m7-ako-management-server-aktualizacia-esxi-pomocou-vsphere-lifecycle-manager-part-6\/\">Cisco UCS C220 M7 vSphere Lifecycle Manager Part 6<\/a><\/li>\n\n\n<li><a href=\"https:\/\/virtualall.sk\/2025\/07\/cisco-ucs-c220-m7-ako-management-server-implementacia-monitoringu-a-centralizovaneho-logovania-part-7\/\">Cisco UCS C220 M7 monitoring a logovanie Part 7<\/a><\/li>\n\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>V tomto pokra\u010dovan\u00ed seri\u00e1lu o budovan\u00ed bezpe\u010dn\u00e9ho VMware klastra sme sa zamerali na n\u00e1vrh sie\u0165ovej architekt\u00fary serverov Cisco UCS C220 M7, ktor\u00e9 s\u00fa zapojen\u00e9 redundatne do dvojice Cisco Nexus prep\u00edna\u010dov. Ka\u017ed\u00fd server vyu\u017e\u00edva dve fyzick\u00e9 sie\u0165ov\u00e9 karty (VIC a MLOM), pri\u010dom ka\u017ed\u00e1 smeruje do in\u00e9ho Nexus switcha, \u010d\u00edm sa dosahuje vysok\u00e1 dostupnos\u0165 a odolnos\u0165 vo\u010di v\u00fdpadku siete. Okrem toho s\u00fa servery medzi sebou priamo prepojen\u00e9 dvoma 25Gbit linkami, ktor\u00e9 s\u00fa dedikovan\u00e9 v\u00fdhradne pre intern\u00fa komunik\u00e1ciu v r\u00e1mci VMotion a Storage vMotion. Na \u00farovni VMware ESXi sme implementovali dve oddelen\u00e9 vSwitch infra\u0161trukt\u00fary \u2013 jedna pre produk\u010dn\u00fd traffic, druh\u00e1 pre syst\u00e9mov\u00e9 oper\u00e1cie. Tento pr\u00edstup zabezpe\u010duje nielen v\u00fdkonnos\u0165 a bezpe\u010dnos\u0165, ale aj preh\u013eadnos\u0165 a jednoduchos\u0165 spr\u00e1vy. V\u010faka vyu\u017eitiu re\u017eimu &#8220;Physical NIC Mode&#8221; na sie\u0165ov\u00fdch kart\u00e1ch zost\u00e1va VLAN tagovanie v plnej r\u00e9\u017eii VMware hyperv\u00edzora, \u010do u\u013eah\u010duje sie\u0165ov\u00fa segment\u00e1ciu a zjednodu\u0161uje konfigur\u00e1ciu. Navrhnut\u00e1 architekt\u00fara tak poskytuje robustn\u00fd z\u00e1klad pre prev\u00e1dzku kritickej infra\u0161trukt\u00fary s d\u00f4razom na \u0161k\u00e1lovate\u013enos\u0165, bezpe\u010dnos\u0165 a vysok\u00fa dostupnos\u0165.<\/p>\n","protected":false},"author":1,"featured_media":1406,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[256,236],"class_list":["post-1403","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vsphere","tag-cisco-server-vmware","tag-cisco-ucs-c220-m7"],"_links":{"self":[{"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/posts\/1403","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/comments?post=1403"}],"version-history":[{"count":8,"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/posts\/1403\/revisions"}],"predecessor-version":[{"id":2350,"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/posts\/1403\/revisions\/2350"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/media\/1406"}],"wp:attachment":[{"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/media?parent=1403"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/categories?post=1403"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/tags?post=1403"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}