{"id":1484,"date":"2025-07-19T10:26:56","date_gmt":"2025-07-19T10:26:56","guid":{"rendered":"https:\/\/virtualall.sk\/?p=1484"},"modified":"2026-09-11T14:38:33","modified_gmt":"2026-09-11T14:38:33","slug":"cisco-ucs-c220-m7-ako-management-server-konfiguracia-vmware-siete-a-vmotion-part-5","status":"publish","type":"post","link":"https:\/\/virtualall.sk\/en\/2025\/07\/cisco-ucs-c220-m7-ako-management-server-konfiguracia-vmware-siete-a-vmotion-part-5\/","title":{"rendered":"Cisco UCS C220 M7 VMware Network and vMotion Part 5"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">V tomto pokra\u010dovan\u00ed seri\u00e1lu o budovan\u00ed bezpe\u010dn\u00e9ho VMware klastra sme sa zamerali na konfigur\u00e1ciu virtu\u00e1lnych switchov (vSwitch), ktor\u00e9 zabezpe\u010duj\u00fa konektivitu pre produk\u010dn\u00e9 VM, spr\u00e1vu, ako aj intern\u00fd prenos VM cez VMotion a Storage vMotion.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">N\u00e1vrh sie\u0165ovej topol\u00f3gie pre VMware klaster s Cisco Nexus prep\u00edna\u010dmi<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Na obr\u00e1zku je zobrazen\u00fd n\u00e1vrh topol\u00f3gie zapojenia dvoch serverov (<code>crsm1<\/code> a <code>crsm2<\/code>), ktor\u00e9 tvoria z\u00e1klad pripravovan\u00e9ho VMware klastra. Ka\u017ed\u00fd server je prepojen\u00fd do dvoch nez\u00e1visl\u00fdch prep\u00edna\u010dov \u2013 <code>Nexus A<\/code> a <code>Nexus B<\/code>, \u010d\u00edm sa zabezpe\u010duje vysok\u00e1 dostupnos\u0165 siete a redundancia uplinkov.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Topol\u00f3gia je rozdelen\u00e1 do dvoch vrstiev:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>vSwitch0<\/strong> (zelen\u00e1 vrstva): sl\u00fa\u017ei ako z\u00e1kladn\u00e1 vrstva pre pripojenie serverov do sie\u0165ovej infra\u0161trukt\u00fary. Tu s\u00fa nakonfigurovan\u00e9 VMkernel porty pre spr\u00e1vu, vMotion a Storage vMotion, pri\u010dom uplinky smeruj\u00fa do oboch Nexus prep\u00edna\u010dov.<\/li>\n\n\n\n<li><strong>vSwitch1<\/strong> (\u017elt\u00e1 vrstva): je vyhraden\u00fd pre intern\u00fa d\u00e1tov\u00fa komunik\u00e1ciu medzi servermi, vyu\u017e\u00edvan\u00fa najm\u00e4 pre vMotion a Storage vMotion. V\u010faka tejto dedikovanej vrstve sa minimalizuje z\u00e1\u0165a\u017e na produk\u010dn\u00fdch uplinkoch a optimalizuje sa r\u00fdchlos\u0165 migr\u00e1ci\u00ed medzi hostami.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"471\" height=\"371\" src=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/siet.png\" alt=\"N\u00e1vrh sie\u0165ovej topol\u00f3gie pre VMware klaster s Cisco Nexus prep\u00edna\u010dmi\" class=\"wp-image-1485\" srcset=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/siet.png 471w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/siet-300x236.png 300w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/siet-15x12.png 15w\" sizes=\"auto, (max-width: 471px) 100vw, 471px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><strong>Krok 1 \u2013 Spustenie pridania nov\u00e9ho virtu\u00e1lneho switcha (vSwitch1)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Na tomto obr\u00e1zku sa nach\u00e1dzame v prostred\u00ed <strong>vSphere Client<\/strong>, na z\u00e1lo\u017eke:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><code>Configure &gt; Networking &gt; Virtual switches<\/code><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hostite\u013e: <code>crsm2<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">V tejto \u010dasti je aktu\u00e1lne zobrazen\u00fd predvolen\u00fd <strong>Standard Switch: vSwitch0<\/strong>, ktor\u00fd sl\u00fa\u017ei na z\u00e1kladn\u00fa sie\u0165ov\u00fa komunik\u00e1ciu (napr. pre spr\u00e1vu hosta).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u27a1\ufe0f Na vytvorenie novej virtu\u00e1lnej siete \u2013 <strong>vSwitch1<\/strong>, ktor\u00fa pou\u017eijeme v\u00fdhradne pre <strong>VMotion<\/strong> a <strong>Storage VMotion<\/strong>, klikneme v pravom hornom rohu na <strong>\u201eAdd Networking\u2026\u201d<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00fdmto sp\u00fa\u0161\u0165ame sprievodcu, kde nakonfigurujeme nov\u00fd vSwitch s VMkernel portom, dedikovan\u00fdm pre d\u00e1tov\u00fa komunik\u00e1ciu medzi hostami.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"376\" src=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-90-1024x376.png\" alt=\"Krok 1 \u2013 Spustenie pridania nov\u00e9ho virtu\u00e1lneho switcha (vSwitch1)\" class=\"wp-image-1486\" srcset=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-90-1024x376.png 1024w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-90-300x110.png 300w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-90-768x282.png 768w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-90-18x7.png 18w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-90.png 1499w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><strong>Krok 2 \u2013 V\u00fdber typu sie\u0165ov\u00e9ho pripojenia (VMkernel Network Adapter)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">V tomto kroku sprievodcu <strong>Add Networking<\/strong> sa nach\u00e1dzame vo f\u00e1ze <strong>\u201eSelect connection type\u201c<\/strong>, kde ur\u010dujeme typ sie\u0165ov\u00e9ho pripojenia, ktor\u00e9 bude vytvoren\u00e9 na ESXi hostovi.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u27a1\ufe0f V tomto pr\u00edpade bola spr\u00e1vne zvolen\u00e1 mo\u017enos\u0165 <strong>\u201eVMkernel Network Adapter\u201c<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e1to vo\u013eba je nevyhnutn\u00e1 v pr\u00edpade, \u017ee chceme nakonfigurova\u0165 sie\u0165ov\u00e9 slu\u017eby ESXi ako s\u00fa:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>vMotion<\/strong><\/li>\n\n\n\n<li><strong>Storage vMotion<\/strong><\/li>\n\n\n\n<li><strong>iSCSI \/ NFS storage<\/strong><\/li>\n\n\n\n<li><strong>vSAN<\/strong><\/li>\n\n\n\n<li><strong>Fault Tolerance<\/strong><\/li>\n\n\n\n<li><strong>Management Network<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Po zvolen\u00ed tejto mo\u017enosti bude mo\u017en\u00e9 priradi\u0165 nov\u00fd alebo existuj\u00faci virtu\u00e1lny switch (napr. vSwitch1) a vytvori\u0165 port, ktor\u00e9mu m\u00f4\u017eeme povoli\u0165 konkr\u00e9tnu slu\u017ebu \u2013 v tomto pr\u00edpade <strong>vMotion<\/strong> a <strong>Storage vMotion<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u27a1\ufe0f Pokra\u010dujeme kliknut\u00edm na <strong>NEXT<\/strong>.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"611\" src=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-92-1024x611.png\" alt=\"Krok 2 \u2013 V\u00fdber typu sie\u0165ov\u00e9ho pripojenia (VMkernel Network Adapter)\" class=\"wp-image-1488\" srcset=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-92-1024x611.png 1024w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-92-300x179.png 300w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-92-768x458.png 768w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-92-18x12.png 18w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-92.png 1145w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><strong>Krok 3 \u2013 V\u00fdber cie\u013eov\u00e9ho zariadenia a vytvorenie nov\u00e9ho vSwitcha<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">V tomto kroku sprievodcu <strong>Add Networking<\/strong> sme vo f\u00e1ze <strong>\u201eSelect target device\u201c<\/strong>, kde ur\u010dujeme, kam sa m\u00e1 nov\u00e1 VMkernel sie\u0165 pripoji\u0165.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u27a1\ufe0f Bola zvolen\u00e1 mo\u017enos\u0165 <strong>\u201eNew standard switch\u201c<\/strong>, \u010d\u00edm vytvor\u00edme nov\u00fd <strong>vSwitch1<\/strong>, ktor\u00fd bude nez\u00e1visl\u00fd od existuj\u00faceho vSwitch0. Tento nov\u00fd switch bude dedikovan\u00fd pre VMotion a Storage vMotion a bude fyzicky prepojen\u00fd na vyhraden\u00e9 25Gbps adapt\u00e9ry medzi hostami.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udd27 <strong>MTU hodnota bola upraven\u00e1 na 9000 bajtov<\/strong>, \u010do je d\u00f4le\u017eit\u00fd krok pre optimaliz\u00e1ciu v\u00fdkonu pri ve\u013ek\u00fdch d\u00e1tov\u00fdch prenosoch \u2013 typick\u00fdch pre vMotion alebo storage migr\u00e1cie.<br>Zv\u00fd\u0161enie MTU na 9000 umo\u017e\u0148uje pou\u017e\u00edvanie <strong>jumbo frame packetov<\/strong>, \u010d\u00edm sa:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>zni\u017euje re\u017eijn\u00e1 z\u00e1\u0165a\u017e na CPU,<\/li>\n\n\n\n<li>zvy\u0161uje priepustnos\u0165,<\/li>\n\n\n\n<li>minimalizuje latencia.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u27a1\ufe0f Pokra\u010dujeme kliknut\u00edm na <strong>NEXT<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"610\" src=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-93-1024x610.png\" alt=\"Krok 3 \u2013 V\u00fdber cie\u013eov\u00e9ho zariadenia a vytvorenie nov\u00e9ho vSwitcha\" class=\"wp-image-1489\" srcset=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-93-1024x610.png 1024w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-93-300x179.png 300w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-93-768x457.png 768w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-93-18x12.png 18w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-93.png 1147w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><strong>Krok 4 \u2013 Priradenie fyzick\u00fdch adapt\u00e9rov k nov\u00e9mu vSwitchu<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">V tomto kroku sa nach\u00e1dzame vo f\u00e1ze <strong>\u201eCreate a Standard Switch\u201c<\/strong>, kde prira\u010fujeme fyzick\u00e9 sie\u0165ov\u00e9 adapt\u00e9ry (<strong>vmnic<\/strong>) k nov\u00e9mu virtu\u00e1lnemu switchu, ktor\u00fd sme sa rozhodli vytvori\u0165.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">V \u010dasti <strong>Active adapters<\/strong> boli pridan\u00e9 dva fyzick\u00e9 sie\u0165ov\u00e9 adapt\u00e9ry:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><code>(New) vmnic5<\/code><\/li>\n\n\n\n<li><code>(New) vmnic2<\/code><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Tieto adapt\u00e9ry bud\u00fa akt\u00edvne pre nov\u00fd vSwitch1 a zabezpe\u010dia:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>priamu konektivitu medzi servermi <code>crsm1<\/code> a <code>crsm2<\/code> (pre vMotion\/Storage vMotion),<\/li>\n\n\n\n<li>vysok\u00fa priepustnos\u0165 (ide o 25Gbps adapt\u00e9ry),<\/li>\n\n\n\n<li>redundanciu.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Nepriraden\u00e9 adapt\u00e9ry s\u00fa zobrazen\u00e9 ni\u017e\u0161ie pod <strong>Unused adapters<\/strong> \u2013 tie mo\u017eno vyu\u017ei\u0165 pre in\u00e9 vSwitche alebo ako z\u00e1lohu (Standby).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u27a1\ufe0f Pokra\u010dujeme kliknut\u00edm na <strong>NEXT<\/strong>.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"609\" src=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-94-1024x609.png\" alt=\"Krok 4 \u2013 Priradenie fyzick\u00fdch adapt\u00e9rov k nov\u00e9mu vSwitchu\" class=\"wp-image-1490\" srcset=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-94-1024x609.png 1024w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-94-300x178.png 300w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-94-768x457.png 768w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-94-18x12.png 18w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-94.png 1148w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><strong>Krok 5 \u2013 Nastavenie vlastnost\u00ed VMkernel portu (Port properties)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">V tomto kroku definujeme vlastnosti nov\u00e9ho <strong>VMkernel portu<\/strong>, ktor\u00fd bude priraden\u00fd k vytvoren\u00e9mu <strong>vSwitch1<\/strong>. Tento port je k\u013e\u00fa\u010dov\u00fd pre zabezpe\u010denie spr\u00e1vnej funkcie slu\u017eieb ako <strong>vMotion<\/strong> alebo <strong>Storage vMotion<\/strong>.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Nastavenia:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Network label:<\/strong> <code>vmotion<\/code><br>\u2192 Tento n\u00e1zov sa zobraz\u00ed ako identifik\u00e1tor portu v sie\u0165ovej \u010dasti ESXi. Odpor\u00fa\u010da sa pomenova\u0165 pod\u013ea funkcie (napr. <code>vmotion<\/code>, <code>storage-vmotion<\/code>, <code>backup<\/code>&#8230;).<\/li>\n\n\n\n<li><strong>VLAN ID:<\/strong> <code>None (0)<\/code><br>\u2192 Znamen\u00e1, \u017ee port komunikuje v nativnej VLAN. Ak by sie\u0165 vMotion bola tagovan\u00e1, je potrebn\u00e9 tu zada\u0165 spr\u00e1vne VLAN \u010d\u00edslo.<\/li>\n\n\n\n<li><strong>MTU:<\/strong> <code>Get MTU from switch<\/code><br>\u2192 Hodnota sa preber\u00e1 z predch\u00e1dzaj\u00faceho nastavenia vSwitchu, ktor\u00e9 bolo nastaven\u00e9 na <strong>9000 bajtov<\/strong> (jumbo frames).<\/li>\n\n\n\n<li><strong>TCP\/IP stack:<\/strong> <code>vMotion<\/code><br>\u2192 V\u00fdber \u0161peci\u00e1lneho TCP\/IP stacku optimalizovan\u00e9ho pre VMotion. Odde\u013euje routovaciu tabu\u013eku od be\u017enej management siete.<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Enabled services:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li> <strong>vMotion<\/strong><br>\u2192 Umo\u017e\u0148uje live migr\u00e1ciu be\u017eiacich VM medzi hostami bez v\u00fdpadku.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u27a1\ufe0f Po nastaven\u00ed t\u00fdchto hodn\u00f4t pokra\u010dujeme kliknut\u00edm na <strong>NEXT<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"613\" src=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-95-1024x613.png\" alt=\"Enabled services:\" class=\"wp-image-1491\" srcset=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-95-1024x613.png 1024w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-95-300x179.png 300w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-95-768x459.png 768w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-95-18x12.png 18w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-95.png 1150w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><strong>Krok 6 \u2013 Nastavenie IPv4 adresy pre VMkernel port<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">V tomto kroku konfigurujeme sie\u0165ov\u00e9 nastavenia pre nov\u00fd <strong>VMkernel port<\/strong>, ktor\u00fd bude pou\u017eit\u00fd na <strong>vMotion<\/strong>.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Zvolen\u00e9 mo\u017enosti:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Use static IPv4 settings<\/strong><br>\u2192 Pou\u017e\u00edvame statick\u00fa IP adresu, \u010do je <strong>odpor\u00fa\u010dan\u00e9 pre VMkernel slu\u017eby<\/strong> ako vMotion, preto\u017ee zaru\u010duje stabiln\u00e9 sie\u0165ov\u00e9 rozhranie medzi ESXi hostmi.<\/li>\n\n\n\n<li><strong>IPv4 address:<\/strong> <code>192.168.211.43<\/code><br>\u2192 T\u00e1to IP adresa mus\u00ed by\u0165 v <strong>rovnakej podsieti ako ostatn\u00e9 VMkernel porty pre vMotion<\/strong> na ostatn\u00fdch ESXi hostoch.<\/li>\n\n\n\n<li><strong>Subnet mask:<\/strong> <code>255.255.255.0<\/code><br>\u2192 Podsie\u0165 pokr\u00fdva rozsah <code>192.168.211.0\/24<\/code>.<\/li>\n\n\n\n<li> <strong>Default gateway<\/strong> je ponechan\u00e1 <strong>nevyplnen\u00e1<\/strong> (neaktivovan\u00e1)<br>\u2192 Pre VMotion sie\u0165 nie je potrebn\u00e1 br\u00e1na (gateway), preto\u017ee komunik\u00e1cia prebieha <strong>iba medzi ESXi hostmi v r\u00e1mci podsiete<\/strong>. V pr\u00edpade oddelenej siete bez routovania je to spr\u00e1vne.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u27a1\ufe0f Po overen\u00ed spr\u00e1vnosti \u00fadajov pokra\u010dujeme kliknut\u00edm na <strong>NEXT<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"629\" src=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-97-1024x629.png\" alt=\"Zvolen\u00e9 mo\u017enosti:\" class=\"wp-image-1493\" srcset=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-97-1024x629.png 1024w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-97-300x184.png 300w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-97-768x472.png 768w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-97-18x12.png 18w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-97.png 1138w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><strong>Krok 7 \u2013 Nastavenie Teaming and Failover na vSwitch1<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Po vytvoren\u00ed <strong>vSwitch1<\/strong> je potrebn\u00e9 upravi\u0165 jeho vlastnosti, aby bola zabezpe\u010den\u00e1 vysok\u00e1 dostupnos\u0165 a spr\u00e1vna detekcia v\u00fdpadkov siete.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">V sekcii <strong>Teaming and failover<\/strong> odpor\u00fa\u010dame nastavi\u0165 nasleduj\u00face parametre:<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Network failure detection: <code>Beacon probing<\/code><\/strong><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Predvolen\u00e1 hodnota b\u00fdva <code>Link status only<\/code>, ktor\u00e1 nedetekuje v\u0161etky typy v\u00fdpadkov (napr. v\u00fdpadok na trase za fyzick\u00fdm portom).<\/li>\n\n\n\n<li><strong>Beacon probing<\/strong> akt\u00edvne vysiela broadcastov\u00e9 pakety cez v\u0161etky akt\u00edvne adapt\u00e9ry a zis\u0165uje, \u010di ich prij\u00edmaj\u00fa ostatn\u00e9 \u2013 v\u010faka tomu detekuje aj \u201etich\u00e9\u201c v\u00fdpadky medzi switchmi.<\/li>\n\n\n\n<li>Odpor\u00fa\u010da sa pri vMotion a in\u00fdch VMkernel slu\u017eb\u00e1ch, kde je <strong>d\u00f4le\u017eit\u00e1 dostupnos\u0165 a redundantn\u00e1 konektivita<\/strong>.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"662\" src=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-96-1024x662.png\" alt=\"Network failure detection: Beacon probing\" class=\"wp-image-1492\" srcset=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-96-1024x662.png 1024w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-96-300x194.png 300w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-96-768x496.png 768w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-96-18x12.png 18w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-96.png 1148w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><strong>Krok 8 \u2013 Spustenie migr\u00e1cie virtu\u00e1lneho stroja<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Na tomto obr\u00e1zku vid\u00edme v\u00fdber <strong>virtu\u00e1lneho stroja <code>test<\/code><\/strong>, ktor\u00fd be\u017e\u00ed na hostovi <code>crsm1<\/code>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Po kliknut\u00ed prav\u00fdm tla\u010didlom my\u0161i na VM sa zobraz\u00ed kontextov\u00e9 menu. Z neho je vybran\u00e1 mo\u017enos\u0165 <strong>\u201eMigrate\u2026\u201c<\/strong>, ktor\u00e1 sl\u00fa\u017ei na presun (migr\u00e1ciu) virtu\u00e1lneho stroja na in\u00fd ESXi host, datastore alebo oboje.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00fdmto krokom za\u010d\u00edna sprievodca <strong>vMotion migr\u00e1ciou<\/strong>, kde budeme pokra\u010dova\u0165 v\u00fdberom typu migr\u00e1cie \u2013 v \u010fal\u0161om kroku vyberieme <strong>presun na in\u00fd host (Compute resource only)<\/strong>, \u010do je typick\u00e9 pre test funk\u010dnosti vMotion siete.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"689\" height=\"471\" src=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-98.png\" alt=\"Krok 8 \u2013 Spustenie migr\u00e1cie virtu\u00e1lneho stroja\" class=\"wp-image-1494\" srcset=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-98.png 689w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-98-300x205.png 300w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-98-18x12.png 18w\" sizes=\"auto, (max-width: 689px) 100vw, 689px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><strong>Krok 9 \u2013 V\u00fdber typu migr\u00e1cie (Select a migration type)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">V tomto kroku sprievodcu migr\u00e1ciou sa rozhodujeme, \u010do presne chceme s virtu\u00e1lnym strojom migrova\u0165.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Zvolen\u00e9:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Change both compute resource and storage<\/strong><br>\u2192 Znamen\u00e1, \u017ee migrujeme:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Compute resource<\/strong> \u2013 VM bude presunut\u00e1 z hosta <code>crsm1<\/code> na hosta <code>crsm2<\/code>.<\/li>\n\n\n\n<li><strong>Storage<\/strong> \u2013 disky VM bud\u00fa presunut\u00e9 z jedn\u00e9ho d\u00e1tov\u00e9ho \u00falo\u017eiska na in\u00e9.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pozn\u00e1mka:<\/strong> Tento typ migr\u00e1cie kombinuje vMotion (presun v\u00fdpo\u010dtov\u00e9ho v\u00fdkonu) a Storage vMotion (presun diskov), tak\u017ee vy\u017eaduje, aby:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>oba hosty mali pr\u00edstup na zdrojov\u00fd a cie\u013eov\u00fd storage (alebo bol zvolen\u00fd kompatibiln\u00fd cie\u013e),<\/li>\n\n\n\n<li>sie\u0165 vMotion aj storage sie\u0165 boli spr\u00e1vne nakonfigurovan\u00e9.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"610\" src=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-99-1024x610.png\" alt=\"Zvolen\u00e9:\" class=\"wp-image-1495\" srcset=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-99-1024x610.png 1024w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-99-300x179.png 300w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-99-768x458.png 768w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-99-18x12.png 18w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-99.png 1151w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><strong>Krok 10 \u2013 V\u00fdber cie\u013eov\u00e9ho hosta (Select a compute resource)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">V tomto kroku si vol\u00edme <strong>cie\u013eov\u00e9ho ESXi hosta<\/strong>, na ktor\u00e9ho chceme presun\u00fa\u0165 virtu\u00e1lny stroj <code>test<\/code>.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Zvolen\u00e1 mo\u017enos\u0165:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>crsm2<\/strong><br>\u2192 Virtu\u00e1lny stroj bude premiestnen\u00fd z hosta <code>crsm1<\/code> na hosta <code>crsm2<\/code>.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Kontrola kompatibility:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">V spodnej \u010dasti obrazovky vid\u00edme spr\u00e1vu:<br><strong>\u201eCompatibility checks succeeded.\u201c<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To znamen\u00e1, \u017ee:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>vybran\u00fd host <strong>sp\u013a\u0148a v\u0161etky po\u017eiadavky na vMotion<\/strong>,<\/li>\n\n\n\n<li>VM je kompatibiln\u00e1 s hardv\u00e9rom a konfigur\u00e1ciou hosta <code>crsm2<\/code>,<\/li>\n\n\n\n<li>pripojen\u00e9 siete, \u00falo\u017eisk\u00e1 a konfigur\u00e1cie VM s\u00fa prenosite\u013en\u00e9.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"609\" src=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-100-1024x609.png\" alt=\"Kontrola kompatibility:\" class=\"wp-image-1496\" srcset=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-100-1024x609.png 1024w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-100-300x178.png 300w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-100-768x456.png 768w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-100-18x12.png 18w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-100.png 1146w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Krok 11 \u2013 V\u00fdber cie\u013eov\u00e9ho \u00falo\u017eiska (Select storage)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">V tomto kroku vyber\u00e1me <strong>storage (datastore)<\/strong>, na ktor\u00fd sa maj\u00fa <strong>presun\u00fa\u0165 disky virtu\u00e1lneho stroja<\/strong> po\u010das migr\u00e1cie.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Zvolen\u00e9:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>crsm2-local<\/strong><br>\u2192 Lok\u00e1lny diskov\u00fd priestor na hostovi <code>crsm2<\/code>, ktor\u00fd m\u00e1:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>kapacitu:<\/strong> 3.36 TB<\/li>\n\n\n\n<li><strong>vo\u013en\u00e9 miesto:<\/strong> 3.36 TB<\/li>\n\n\n\n<li><strong>obsaden\u00e9:<\/strong> len 1.47 GB<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Tento krok je s\u00fa\u010das\u0165ou <strong>Storage vMotion<\/strong>, kde sa disky VM fyzicky premiest\u0148uj\u00fa na in\u00fd storage.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u010eal\u0161ie mo\u017enosti:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Select virtual disk format:<\/strong> zvolen\u00fd \u201eSame format as source\u201c<br>\u2192 zachov\u00e1va aktu\u00e1lny form\u00e1t disku (napr. thick alebo thin provisioned)<\/li>\n\n\n\n<li><strong>VM Storage Policy:<\/strong> \u201eKeep existing VM storage policies\u201c<br>\u2192 \u017eiadna zmena politiky \u00falo\u017eiska<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Compatibility checks succeeded<\/strong>:<br>\u2192 V\u0161etky po\u017eiadavky pre migr\u00e1ciu na tento storage boli \u00faspe\u0161ne overen\u00e9.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"613\" src=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-101-1024x613.png\" alt=\"\u010eal\u0161ie mo\u017enosti:\" class=\"wp-image-1497\" srcset=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-101-1024x613.png 1024w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-101-300x180.png 300w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-101-768x460.png 768w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-101-18x12.png 18w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-101.png 1142w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><strong>Krok 12 \u2013 V\u00fdber cie\u013eovej siete (Select networks)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">V tomto kroku ur\u010duje\u0161, <strong>do ktorej virtu\u00e1lnej siete bude VM pripojen\u00e1 po migr\u00e1cii<\/strong> na nov\u00fd host <code>crsm2<\/code>.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Zobrazen\u00e9:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Source Network:<\/strong> <code>VM Network<\/code><br>\u2192 Toto je aktu\u00e1lna sie\u0165, do ktorej je VM pripojen\u00e1 na p\u00f4vodnom hoste <code>crsm1<\/code>.<\/li>\n\n\n\n<li><strong>Destination Network:<\/strong> <code>VM Network<\/code><br>\u2192 Vybran\u00e1 cie\u013eov\u00e1 sie\u0165 na hoste <code>crsm2<\/code>. Mala by to by\u0165 <strong>rovnak\u00e1 portov\u00e1 skupina<\/strong>, aby VM po migr\u00e1cii nestratila konektivitu.<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Kompatibilita:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u2714 <strong>Compatibility checks succeeded<\/strong><br>\u2192 Sie\u0165 s rovnak\u00fdm n\u00e1zvom je dostupn\u00e1 aj na cie\u013eovom hoste. Pripojenie VM zostane zachovan\u00e9 bez potreby manu\u00e1lnej rekonfigur\u00e1cie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Odpor\u00fa\u010danie:<\/strong><br>Ak pou\u017e\u00edva\u0161 <strong>standard switches (vSwitch0)<\/strong>, portov\u00e1 skupina s rovnak\u00fdm n\u00e1zvom mus\u00ed by\u0165 vytvoren\u00e1 manu\u00e1lne na v\u0161etk\u00fdch hostoch.<br>V prostred\u00ed s <strong>distributed switchom (VDS)<\/strong> je t\u00e1to \u010das\u0165 automatizovan\u00e1 a sie\u0165ov\u00e1 konektivita je v\u017edy konzistentn\u00e1.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"609\" src=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-102-1024x609.png\" alt=\"Kompatibilita:\" class=\"wp-image-1498\" srcset=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-102-1024x609.png 1024w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-102-300x178.png 300w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-102-768x456.png 768w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-102-18x12.png 18w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-102.png 1146w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><strong>Krok 13 \u2013 V\u00fdber priority pre vMotion (Select vMotion priority)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Tento krok ti umo\u017e\u0148uje zvoli\u0165, <strong>ak\u00fa prioritu m\u00e1 ma\u0165 migr\u00e1cia VM<\/strong> z h\u013eadiska vyu\u017eitia CPU a r\u00fdchlosti dokon\u010denia.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Dostupn\u00e9 mo\u017enosti:<\/h4>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Schedule vMotion with high priority (odpor\u00fa\u010dan\u00e9)<\/strong><br>Aktu\u00e1lne zvolen\u00e1 mo\u017enos\u0165<br>\u2192 vMotion dostane vy\u0161\u0161iu prioritu pri pl\u00e1novan\u00ed CPU prostriedkov, \u010do zabezpe\u010d\u00ed r\u00fdchlej\u0161ie dokon\u010denie migr\u00e1cie.<\/li>\n\n\n\n<li><strong>Schedule normal vMotion<\/strong><br>\u2192 vMotion bude ma\u0165 ni\u017e\u0161iu prioritu, m\u00f4\u017ee trva\u0165 dlh\u0161ie, ale bude ma\u0165 men\u0161\u00ed dopad na be\u017eiace \u00falohy v syst\u00e9me.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h4 class=\"wp-block-heading\">Kedy zvoli\u0165 &#8220;high priority&#8221;:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pri <strong>akt\u00edvne be\u017eiacej VM<\/strong>, kde je d\u00f4le\u017eit\u00e1 r\u00fdchla a bezv\u00fdpadkov\u00e1 migr\u00e1cia.<\/li>\n\n\n\n<li>Pri <strong>\u00fadr\u017ebe hosta<\/strong>, kde sa pl\u00e1nuje odpojenie zdroja po migr\u00e1cii.<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Kedy zvoli\u0165 &#8220;normal vMotion&#8221;:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pri pl\u00e1novan\u00fdch migr\u00e1ci\u00e1ch mimo \u0161pi\u010dku alebo pri <strong>migr\u00e1cii viacer\u00fdch VM s\u00fa\u010dasne<\/strong>, aby sa rovnomerne rozdelilo za\u0165a\u017eenie.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"610\" src=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-103-1024x610.png\" alt=\"Kedy zvoli\u0165 &quot;normal vMotion&quot;:\" class=\"wp-image-1499\" srcset=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-103-1024x610.png 1024w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-103-300x179.png 300w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-103-768x457.png 768w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-103-18x12.png 18w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-103.png 1139w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Po migr\u00e1cii vid\u00edme, \u017ee:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Virtu\u00e1lna ma\u0161ina <code>test<\/code> bola \u00faspe\u0161ne premiestnen\u00e1 z hosta <code>crsm1<\/code> na hosta <code>crsm2<\/code><\/strong>.<\/li>\n\n\n\n<li>Ikonka VM <code>test<\/code> sa teraz nach\u00e1dza pod <code>crsm2<\/code>.<\/li>\n\n\n\n<li>Na hoste <code>crsm1<\/code> u\u017e nie je \u017eiadna be\u017eiaca VM s n\u00e1zvom <code>test<\/code>.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">V\u00fdsledok migr\u00e1cie:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Migr\u00e1cia <strong>prebehla \u00faspe\u0161ne<\/strong>.<\/li>\n\n\n\n<li><strong>Compute zdroj aj storage<\/strong> boli presunut\u00e9 pod\u013ea zvolen\u00e9ho typu migr\u00e1cie.<\/li>\n\n\n\n<li>Sie\u0165ov\u00e9 pripojenie bolo zachovan\u00e9 cez rovnak\u00fd &#8220;VM Network&#8221;.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"369\" height=\"164\" src=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-104.png\" alt=\"V\u00fdsledok migr\u00e1cie:\" class=\"wp-image-1500\" srcset=\"https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-104.png 369w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-104-300x133.png 300w, https:\/\/virtualall.sk\/wp-content\/uploads\/2025\/07\/obrazek-104-18x8.png 18w\" sizes=\"auto, (max-width: 369px) 100vw, 369px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Cel\u00e1 s\u00e9ria: Cisco UCS C220 M7<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n\n<li><a href=\"https:\/\/virtualall.sk\/2025\/07\/cisco-ucs-c220-m7-ako-zaklad-pre-bezpecny-vmware-klaster-pre-management-a-zalohovanie\/\">Cisco UCS C220 M7 VMware klaster<\/a><\/li>\n\n\n<li><a href=\"https:\/\/virtualall.sk\/2025\/07\/cisco-ucs-c220-m7-ako-zaklad-pre-bezpecny-vmware-klaster-pre-management-a-zalohovanie-part-2\/\">Cisco UCS C220 M7 VMware klaster Part 2<\/a><\/li>\n\n\n<li><a href=\"https:\/\/virtualall.sk\/2025\/07\/cisco-ucs-c220-m7-ako-management-server-sietova-architektura-pre-vmware-klaster-part-3\/\">Cisco UCS C220 M7 sie\u0165ov\u00e1 architekt\u00fara Part 3<\/a><\/li>\n\n\n<li><a href=\"https:\/\/virtualall.sk\/2025\/07\/cisco-ucs-c220-m7-ako-management-server-instalacia-vmware-esxi-a-vcenter-pre-spravu-klastra-part-4\/\">Cisco UCS C220 M7 ESXi a vCenter Part 4<\/a><\/li>\n\n\n<li><strong>Cisco UCS C220 M7 VMware sie\u0165 a vMotion Part 5<\/strong> &mdash; tento \u010dl\u00e1nok<\/li>\n\n\n<li><a href=\"https:\/\/virtualall.sk\/2025\/07\/cisco-ucs-c220-m7-ako-management-server-aktualizacia-esxi-pomocou-vsphere-lifecycle-manager-part-6\/\">Cisco UCS C220 M7 vSphere Lifecycle Manager Part 6<\/a><\/li>\n\n\n<li><a href=\"https:\/\/virtualall.sk\/2025\/07\/cisco-ucs-c220-m7-ako-management-server-implementacia-monitoringu-a-centralizovaneho-logovania-part-7\/\">Cisco UCS C220 M7 monitoring a logovanie Part 7<\/a><\/li>\n\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>V tomto pokra\u010dovan\u00ed seri\u00e1lu o budovan\u00ed bezpe\u010dn\u00e9ho VMware klastra sme sa zamerali na praktick\u00e9 overenie funk\u010dnosti vMotion migr\u00e1cie medzi dvoma fyzick\u00fdmi ESXi servermi v prostred\u00ed spravovanom cez vCenter Server. Po \u00faspe\u0161nej in\u0161tal\u00e1cii a pripojen\u00ed oboch ESXi hostov do vCentra sme vytvorili nov\u00fa testovaciu virtu\u00e1lnu ma\u0161inu s n\u00e1zvom test, ktor\u00e1 bola umiestnen\u00e1 na prvom hoste crsm1. N\u00e1sledne sme prist\u00fapili k simul\u00e1cii migr\u00e1cie tejto virtu\u00e1lnej ma\u0161iny pomocou vMotion.<\/p>\n","protected":false},"author":1,"featured_media":1503,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[256,236],"class_list":["post-1484","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vsphere","tag-cisco-server-vmware","tag-cisco-ucs-c220-m7"],"_links":{"self":[{"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/posts\/1484","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/comments?post=1484"}],"version-history":[{"count":9,"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/posts\/1484\/revisions"}],"predecessor-version":[{"id":2352,"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/posts\/1484\/revisions\/2352"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/media\/1503"}],"wp:attachment":[{"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/media?parent=1484"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/categories?post=1484"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/virtualall.sk\/en\/wp-json\/wp\/v2\/tags?post=1484"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}